64 51 520 Removing and Installing Or Replacing Expansion Valve
Risk of injury!
Refrigerant circuit is under high pressure!
Handling R134a refrigerant: see SAFETY INSTRUCTIONS and INSTRUCTIONS FOR HANDLING .
Avoid contact with refrigerant and refrigerant oil.
Handling refrigerant oil: see safety instructions for HANDLING REFRIGERANT OIL (FOR REFRIGERANT R134A) .
Risk of damage!
Restart engine only when A/C system has been correctly filled.
Follow INSTRUCTIONS FOR OPENING AND REPLACING PARTS IN REFRIGERANT CIRCUIT .
Necessary preliminary tasks:
- Drain off refrigerant from A/C system. See DRAWING OFF, EVACUATING AND FILLING A/C SYSTEM (R134A) .
- Remove lower section of microfilter housing. Refer to REMOVING AND INSTALLING/REPLACING MICROFILTER HOUSING (LOWER SECTION) .
Release screws (1, 2), disconnect refrigerant lines and lay to one side.
Installation:
Replace all sealing rings and moisten with refrigerant oil.
Tightening torque 64 53 2AZ
Release screws (1) and remove expansion valve (2).
Tightening torque 64 53 13AZ
Installation:
Place expansion valve (1) exactly on refrigerant lines (2) and (3).
Fit screws of expansion valve (1) and make sure retainer (4) is correctly positioned.
After installation:
- Evacuate and fill A/C system. Refer to DRAWING OFF, EVACUATING AND FILLING A/C SYSTEM (R134A) .