LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2009 >> 650i 2D Convertible, Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 2047 (HVAC System - Repair) >> Ac Housing/Evaporator >> 64 51 001 Cleaning Evaporator

64 51 001 Cleaning Evaporator

WARNING: This page is about a different car, the 2010 BMW 135i, 2009 BMW 135i, and 2008 BMW 135i. However, it is still accessible from the selected car via links, so may be relevant.

Special Tools Required 

WARNING:

When handling cleaning agent, observe following protection measures:

Wear protective rubber gloves and protective goggles.

If cleaning agent comes into contact with eyes or skin, wash immediately with lots of water.

IMPORTANT: To avoid dirtying vehicle interior:
  • Close all air vents.
  • Switch heating - A/C system to recirculated-air mode.
  • Cover carpet in work area.

Recycling: 

Carry out the cleaning operation in a suitable washing bay as the emerging cleaning agent escapes through the drain openings in the transmission tunnel.

After completing cleaning, allow car to drip-dry for approx. 5 minutes.

Necessary preliminary tasks: 

IMPORTANT: Use special tool 64 1 270  on right hand drive models.

Connect special tool 64 1 260  (spray lance) to spray gun (2).

Insert 64 1 260  through opening (1) into fresh air duct.

By moving spray lance (1) back and forth, spray a uniform amount of cleaning agent onto evaporator.

Fig 1: Inserting Spray Lance Into Fresh Air Duct
G04727876Courtesy of BMW OF NORTH AMERICA, INC.

64 1 260  shown on removed and cut-open heater/air conditioner:

By moving spray lance back and forth, spray a uniform amount of cleaning agent onto evaporator.

Fig 2: Identifying Spray Lance Move Position
G04727877Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: Set heating - A/C system to footwell ventilation and fresh-air mode. Open windows/doors.

Start car and run heating - A/C system at maximum fan power for approx. 5 minutes in order to dry evaporator.

In order to eliminate the last remnants of cleaning agent, repeat this procedure shortly before handover to the customer.