64 11 324 Replacing button caps of heater controls (E60/E61 to 02/2007, E63/E64 to 08/2007)

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2010 BMW 528xi, 2010 BMW 528i, 2009 BMW 528xi, 2009 BMW 528i, and 2008 BMW 528xi. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

Turn temperature selector wheel (1) to stop (arrow).

NOTE: Air volume control (2) has no limit position.
Fig 1: Identifying Temperature Selector Wheels And Air Volume Control
G00528599

Unclip the protective cap (1) of the temperature selector wheels and air flow controller with button cap (2) in direction of arrow.

Fig 2: Identifying Protective Cap And Button Cap
G00528600

Installation note:  Mark (1) must be aligned with mark (2) of the protective cap of the air flow controller (3).

Fig 3: Aligning Marks
G00528601

Installation note:  Clip protective cap (1) of the left temperature selector wheel in with mark pointing to the left (arrow). Clip the protective cap of the right temperature selector wheel in with mark pointing to the right. Protective caps must audibly snap into place.

Fig 4: Clip Protective Cap Of Left Temperature Sensor
G00528602

Mask button caps as shown with adhesive tape (1).

Fig 5: Masking Button Caps With Tape
G00528603

Lever off button caps (1) with special tool 00 9 341.

Fig 6: Levering Off Button Caps
G00528604

Remove adhesive tape (1). Pull light piece (2) out of the fixture of the operating facility using a suitable tool.

Fig 7: Removing Light Piece Out Of Fixture
G00528605

Detach the button caps (1) from the die cast tree (2). Carefully deburr the button caps, if applicable.

Fig 8: Detaching Button Caps From Die Cast Tree
G00528606

Clip light elements (1) into the button caps (2) as shown. Clip button caps into the operating unit. Installation note:  The button cap for air recirculation function has two light elements.

Fig 9: Clipping Light Elements Into Button Caps
G00528607

Check function of the air conditioning.