64 50 ... Leak-Testing With Leak Tester Device
Avoid contact with refrigerant.
Follow safety precautions when handling refrigerant. See 64 50 ... INSTRUCTIONS FOR HANDLING REFRIGERANT R 134A
Carry out leak-testing with a leak tester device from the workshop equipment catalog following the device manufacturer's operating instructions.
If leaks not to be localized are already identified during evacuation, the A/C system must nevertheless be filled . Then test for leaks with leak tester device. See 64 50 009 DRAWING OFF, EVACUATING AND FILLING A/C SYSTEM (R 134A)
Refrigerant is heavier than air.
Therefore always conduct the leak test below the lines and components to be tested.
Shield lines and components against strong blasts of air (wind, drawing off).
Tighten down loose lines, mark leaks.
Then draw off A/C system and seal off or repair leakage points. See 64 50 009 DRAWING OFF, EVACUATING AND FILLING A/C SYSTEM (R 134A)
Then refill A/C system and test for leaks. See 64 50 009 DRAWING OFF, EVACUATING AND FILLING A/C SYSTEM (R 134A)