17 00 009 Checking cooling system for leaks (N62)
Special tools required:
Danger of scalding!
Only perform this work after engine has cooled down.
Checking for leaks in cooling circuit:
Open cap on coolant expansion tank.
Fit special tool 17 0 002 /17 0 005 .
Build up gauge pressure of 1.5 bar, wait approx. 2 minutes.
Cooling system is leak-free if pressure drop is max. 0.1 bar.
Checking function of cap:
Detach rubber (1) from special tool 17 0 002 .
Fit special tool 17 0 007 /17 0 008 .
Screw cap (1) onto special tool 17 0 007 .
Pressure relief valve must open between 1.65 and 2.2 bar.
Build up pressure with special tool 17 0 002 and watch pressure gauge to ascertain when opening pressure is reached. Note down measured opening pressure.
After a waiting period of approx. 30 seconds, the pressure must no longer drop by more than 0.4 bar below the measured opening pressure.