34 00 050 Bleeding Brake System With DSC: Notes
WARNING: This page is about a different car, the 2010 BMW M5, 2009 BMW M5, 2008 BMW M5, 2007 BMW M5, and 2006 BMW M5. However, it is still accessible from the selected car via links, so may be relevant.
Necessary preliminary tasks:
- Remove lower section of microfilter housing. See 64 31 061 REMOVING AND INSTALLING/REPLACING LEFT OR RIGHT MICROFILTER HOUSING LOWER SECTION .
- Read and comply with General Information .
Observe the filling and bleeding instructions when replacing or repairing:
- Brake master cylinder
- Hydraulic unit
- Components and connecting lines which are fitted between these assemblies.
Connect bleeder unit with max. 2 bar filling pressure.
A second person is needed to help carry out this work.
- Connect BMW Diagnosis and Information System (DIS).
- Select path: Service functions - Chassis/Suspension - Slip control systems - Bleeding procedure.
- Connect bleeder unit to expansion tank and switch on.
IMPORTANT:
Check relevant Operating Instructions for each device.
Charging pressure should not exceed 2 bar.
Charging pressure should not exceed 2 bar.