1.15.8.1 Electrical checks
P0113 (TAEmax), P0112 (TAEmin), P0110 (TAEnpl)
The electrical check detects out of range values by comparing the temperature-dependent voltage of the intake air temperature sensor with an upper and lower calibrated thresholds. A TAEmax fault will be set if the voltage exceeds the upper calibrated threshold for a calibrated period of time. Likewise, a TAE min fault will be set if it undershoots the lower calibrated threshold for a calibrated period of time.
An intermittent contact may result in frequent jumps of the measured intake air temperature signal. A signal jump is detected by evaluation of the difference between the measured intake air temperature and the filtered intake air temperature. If this difference exceeds a calibrated value a jump-detected-timer with a calibrated time length is started and retriggered every time the difference exceeds again the calibrated value (multiple jumps).
If the overall time of the retriggered and as a result continuously running "jump-detected-timer" exceeds a calibrated period of time, an intermittent contact is detected and a TAEnpl fault will be set.