61 20 503 Vehicle Battery - Closed-Circuit Current Monitoring

WARNING: This page is about a different variant/trim than selected.

Necessary preliminary tasks:  To access negative lead of battery, perform the necessary preliminary work described in Disconnecting negative battery cable . Do not disconnect negative lead of battery.

Connect BMW diagnosis system.  Connect clip-on probe to negative lead of battery. The arrow on the current clamp must point towards the battery. Measure closed-circuit current using diagnosis system.