64 53 520 Replacing Safety Pressure Switch
Risk of injury!
Refrigerant circuit is under high pressure!
Follow safety instructions for handling R 134a refrigerant . See 64 50... Instructions For Handling Refrigerant R134a and/or 64 50... Safety Instructions For Handling Refrigerant R134A .
Avoid contact with refrigerant and refrigerant oil.
Follow safety instructions for handling refrigerant oil . Refer to 64 50... Instructions For Handling Refrigerant Oil (For Refrigerant R134a) .
Risk of damage!
Restart engine only when A/C system has been correctly filled.
Follow instructions for opening and replacing parts in refrigerant circuit. Refer to 64 52... Instructions For Opening And Replacing Parts In Refrigerant Circuit .
If A/C system is opened for more than 24 hours:Replace desiccant insert for A/C system . Refer to 64 53 515 Replacing Desiccant Insert For A/C System .
Necessary preliminary tasks:
- Drawing off, evacuating and filling the A/C system are not included in the time value given for this work operation. Refer to 64 50 009 Drawing Off, Evacuating And Filling A/C System (R134A)
Release screws (1) and bent heat insulation (2) to one side slightly.
Disconnect plug connection (1) and release safety pressure switch (2).
Tightening torque, see 64 53 14AZ in 64 53 REFRIGERANT LINES AND EXPANSION VALVE .
After installation:
- Evacuate and fill A/C system Refer to 64 50 009 Drawing Off, Evacuating And Filling A/C System (R134A) .