64 51 520 Removing and Installing Or Replacing Expansion Valve
Risk of injury!
Refrigerant circuit is under high pressure!
Follow safety instructions for handling R 134a refrigerant . See 64 50... Instructions For Handling Refrigerant R134a and/or 64 50... Safety Instructions For Handling Refrigerant R134A .
Avoid contact with refrigerant and refrigerant oil.
Follow safety instructions for handling refrigerant oil . Refer to 64 50... Instructions For Handling Refrigerant Oil (For Refrigerant R134a) .
Risk of damage!
Restart engine only when A/C system has been correctly filled.
Follow instructions for opening and replacing parts in refrigerant circuit! Refer to 64 52... Instructions For Opening And Replacing Parts In Refrigerant Circuit .
Necessary preliminary tasks:
- Drawing off, evacuating and filling the A/C system are not included in the time value given for this work operation. Refer to 64 50 009 Drawing Off, Evacuating And Filling A/C System (R134A) .
- Remove lower section of microfilter housing . Refer to 64 31 081 Removing And Installing/Replacing Microfilter Housing (Upper Section) .
Release screws (1, 2), disconnect refrigerant lines and lay to one side.
Installation:
Replace all sealing rings and moisten with refrigerant oil.
Tightening torque, see 64 53 2AZ in 64 53 REFRIGERANT LINES AND EXPANSION VALVE .
Release screws (1) and remove expansion valve (2).
Tightening torque, see 64 53 13AZ in 64 53 REFRIGERANT LINES AND EXPANSION VALVE .
Installation:
Place expansion valve (1) exactly on refrigerant lines (2) and (3).
Fit screws of expansion valve (1) and make sure retainer (4) is correctly positioned.
After installation:
- Evacuate and fill A/C system . Refer to 64 50 009 Drawing Off, Evacuating And Filling A/C System (R134A) .