12 42 500 Replacing battery positive lead (between starter, alternator and battery positive terminal)
Necessary preliminary tasks:
- Read out fault memory of DME control unit
- Switch off ignition
- Disconnect battery negative lead . See 61 20 900 DISCONNECTING AND CONNECTING BATTERY NEGATIVE LEAD .
- Remove intake air manifold . See 11 61 050 REMOVING AND INSTALLING INTAKE AIR MANIFOLD (N54, N54T) .
Remove protective cap (not shown).
Release screw, remove battery positive lead (1) from battery positive terminal.
Tightening torque 12 42 3AZ, see 12 42 ALTERNATOR LEAD .
Remove protective cap and release nut underneath.
Tightening torque 12 42 1AZ, see 12 42 ALTERNATOR LEAD .
Disconnect battery positive lead (1) from alternator.
Unlock plug (1) and remove.
Unfasten nut.
Tightening torque 12 42 2AZ, see 12 42 ALTERNATOR LEAD .
Disconnect battery positive lead (2) from starter motor.
Unclip battery positive lead (1) from holder (2) and remove.
NOTE:
Check stored fault messages.
Now clear the fault memory.
Now clear the fault memory.