12 14 521 Replacing crankshaft pulse generator (N52, N52K, N51, N53)
No steel screws/bolts may be used due to the threat of electrochemical corrosion.
A magnesium crankcase requires aluminium screws/bolts exclusively.
Aluminium screws/bolts must be replaced each time they are released.
The end faces of aluminium screws/bolts are painted blue for the purposes of reliable identification.
Jointing torque and angle of rotation must be observed without fail (risk of damage ).
Necessary preliminary tasks:
- Read out fault memory of DME control unit
- Switch off ignition
Preparatory tasks:
- Remove INTAKE MANIFOLD
Detach plug (1) from crankshaft pulse generator (2).
Release screw.
Installation:
Replace aluminium screws.
For tightening torque refer to 12 14 2AZ in 12 14 ELECTRONIC SHIFT UNITS OR CONTROL UNITS .
Withdraw pulse generator (2) from crankcase.
Installation:
Replace sealing ring.
Now clear the fault memory.