12 41 Starter And Mounting Parts
STARTER AND MOUNTING PARTS - TIGHTENING TORQUE SPECIFICATIONS (1AZ - 6AZ)
| Type | Thread | Tightening specification | Measure | |
|---|---|---|---|---|
| 1AZ Starter motor mounting to transmission bell housing | All | 45 N.m. | ||
| 2AZ Support to starter | All | M5 | 5 N.m. | |
| 3AZ Support to crankcase | All | 47 N.m. | ||
| 4AZ Electrical leads to starter | ||||
| All | M5 | f5 N.m. | ||
| All | M6 | 7 N.m. | ||
| All | M8 | 13 N.m. | ||
| 5AZ Bolt connection, pole tube | All | M6 | 6 N.m. | |
| 6AZ Heat shield to starter motor | M6 | 6 N.m. |