LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2008 >> 750i >> Repair and Diagnosis >> External Pages >> Different car >> Section 105 (Diagnostic Trouble Codes With Test Charts (V8 & V12)) >> Test Group Diagnosis >> Catalyst Monitoring >> Notes

Catalyst Monitoring: Notes

WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2001 BMW Z8, 2001 BMW X5, 2001 BMW M5, 2001 BMW 750iL, and 2001 BMW 740iL. However, it is still accessible from the selected car via links, so may be relevant.

Efficiency of catalyst operation is determined by evaluating oxygen storage capability of catalytic converter using pre and post oxygen sensor signals. A correctly operating catalyst consumes or stores most of oxygen present in exhaust gas. To determine if catalyst is working correctly, signal of post cat oxygen sensor is evaluated over course of several pre-catalytic oxygen sensor oscillations. During evaluation period, signal of post-catalytic sensor must remain within a relatively constant voltage range.

Under normal closed loop operation, changing air/fuel ratio in exhaust gas results in lambda oscillations at pre-catalyst sensor. These oscillations are dampened by oxygen storage activity of catalyst and are reflected at post-catalyst sensor as a fairly stable signal. Depending on how vehicle is being operated at time of evaluation and type of catalyst or coating being used, signal may be in lean or rich voltage range.

CATALYST SENSOR MONITORING CONDITIONS

Condition Specification
Closed Loop Operation Yes
Engine Coolant Temperature Operating Temperature
Vehicle Road Speed 3-50 MPH
Catalyst Temperature 661-1201°F (350-650°C)
Throttle Angle Deviation Steady Throttle
Engine Speed Deviation Steady/Stable Engine Speed
Average Lambda Value Deviation Steady/Stable Load