Repair procedures (plant/service)
- Determine whether battery sensor is installed. If not, use SGBD to delete all adaptation data and then switch ignition off/on.
- Check continuity in wire connecting DME to battery sensor (BSD_BUS)
- Ensure correct fit of battery sensor on battery ground terminal and check seating of all plugs
- Replace battery sensor.