12 42 500 Replacing battery positive lead (between starter, alternator and battery positive terminal)
Necessary preliminary tasks:
- Read out fault memory of DME control unit
- Switch off ignition
- Disconnect battery negative lead
Observe instructions for disconnecting and connecting battery
- Remove intake air manifold
Release screw, remove battery positive lead (1) from battery positive terminal.
Tightening torque 12 42 1AZ .
Release nut and remove battery positive lead (1) from alternator.
Tightening torque 12 31 1AZ .
Unlock plug (1) and remove.
Unfasten nut.
Tightening torque 12 41 3AZ .
Detach battery positive lead (2) from starter motor and remove.
NOTE:
Check stored fault messages.
Now clear the fault memory.
Now clear the fault memory.