Monitoring description: Notes
For a variable valve lift engine, the main function of the throttle body is to control the pressure in the intake manifold. Therefore the manifold differential pressure plausibility check is testing the plausibility of measured intake manifold pressure in comparison to the measured throttle position. So no throttle position acquisition error must be present.
The set-point of the differential intake manifold pressure is up to 60-70% of maximum torque request constant 5 kPa beneath ambient pressure. At higher load the differential pressure set-point becomes Zero.
In case the set-point of the differential pressure in the intake manifold is > 3 kPa beneath the ambient pressure, a differential pressure controller is active. The output of the controller is monitored. The output of the manifold pressure controller has to be between adjustable MIN/MAX-thresholds. If the MIN/MAX thresholds are exceeded a time counter is incremented. After this counter reaches the threshold within one diagnosis cycle, a manifold differential pressure sensor malfunction is detected.