Monitoring function - pump current diagnosis
P1434, P1447, P1448, P1449
In the reference measurement phase the current of the DM-TL is checked, if the current consumption is smaller than 15 mA a defect pump/motor is detected, and P1448 is stored. If a current consumption of bigger than 40 mA is measured also a defect pump/motor is detected, and the P1449 is stored.
After the reference measurement the electrical solenoid is switched and the venting system is tight. The solenoid is checked by comparison of the reference current and the idle current immediately after the solenoid has switched.
If the difference between the two currents (reference current - idle current) > 2 mA is not reached, the DTC P1447 is stored.
The P1434 fault code is set, if current fluctuations (caused by humidity in the DM-TL) > 1 mA are detected.