Repair procedures (plant/service)
- Check Terminal 15/wakeup wire for opens and intermittent contacts
- With battery sensor removed and Terminal 15 off, check Terminal 15/wakeup wire for short to battery voltage -> Repair wire and/or check Terminal 15, control module wakeup
- With battery sensor removed and Terminal 15 on, check Terminal 15/wakeup wire for short to ground
- With battery sensor connected and Terminal 15 off, check Terminal 15/wakeup wire for shorts to battery voltage - > Replace battery sensor
- With battery sensor connected and Terminal 15 on, check Terminal 15/wakeup wire for shorts to ground -> Replace battery sensor