12 42 500 Replacing battery positive lead (between starter, alternator and battery positive terminal)
Necessary preliminary tasks:
- Read out fault memory of DME control unit
- Switch off ignition
- Disconnect Battery Negative Lead
Follow Instructions For Disconnecting And Connecting Battery
- Remove Intake Air Manifold
Remove protective cap (not shown).
Release nut, remove battery positive lead (1) from battery positive terminal.
Tightening torque 12 42 1AZ in STARTER LEAD .
Release nut and remove battery positive lead (1) from alternator.
Tightening torque 12 31 1AZ.
Unlock plug (1) and remove.
Unfasten nut.
For tightening torque refer to 12 41 3AZ in 12 41 STARTER MOTOR WITH MOUNTING .
Detach battery positive lead (2) from starter motor and remove.
NOTE:
Check stored fault messages.
Now clear the fault memory.