11 14 010 Replacing vacuum pump sealing cover (N52)
Special tools required:
- 11 4 361
- 11 4 362
- 11 4 363
- 11 4 364
- 11 9 200
Necessary preliminary tasks:
- Remove fan cowl.
- Remove Alternator Drive Belt.
- Remove Tensioner For Drive Belt.
NOTE:
Procedure is identical to that for radial shaft seal.
Expose removal openings on sealing cover.
Convert special tool 11 9 200 (see Fig 2).
Screw special tool 11 9 200 onto end cover.
NOTE:
Insert screws until flush only with special tool 11 9 200.
Screw in special tool 11 4 362.
Attach special tool 11 4 361 to Bedplate screw connection (see arrow in Fig 4).
Secure with knurled screw (1).
Screw special tool 11 4 364 into special tool 11 9 200 and screw out in direction of arrow.
NOTE:
For purposes of clarity, illustrations show alternator and servo pump.
Prepare new sealing cover (1) with special tool 11 9 200 without screws.
Screw in sealing cover with special tool 11 4 363 until it is flush.
Assemble engine.