LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2007 >> 335i 2D Convertible, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 9 (General Electrical System - Repair - E90/91) >> 13 Plug connection, terminals, fuse box >> 61 13 ... Crimping Micro Power Quadlock contacts (MPQ)

61 13 ... Crimping Micro Power Quadlock contacts (MPQ)

WARNING: This page is about a different variant/trim than selected.

Special tools required: 

To crimp MPQ contacts, use pliers 61 4 321 (1) in conjunction with crimping head 61 4 325 (2) from crimping set 61 4 320.

NOTE: Pliers (1) open automatically as far as they will go when handles are pressed together.
Fig 1: Identifying Special Tools (61 4 321) Pliers And (61 4 325) Crimping Head
G04727513Courtesy of BMW OF NORTH AMERICA, INC.

Open pliers (1).

NOTE: Place contact (2) with utmost care in designated nest (observe cable cross-section) in crimping head (3). Make sure it is exactly positioned.

Place MPQ contact (2) in crimping head (3).

Close pliers (1) one notch.

Fig 2: Identifying Special Tools (61 4 321) / (61 4 325) Contact, Crimping Head And Pliers
G04727514Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: Follow procedure for Cutting And Stripping Insulation  from cables.

Insert stripped cable (2).

Close pliers (1) fully.

Open pliers (1) and remove cable (2).

Fig 3: Identifying Special Tools (61 4 321) / (61 4 325) Pliers And Cable
G04727515Courtesy of BMW OF NORTH AMERICA, INC.