Monitoring criteria
Knock sensor signal monitor. Vehicle road operation at >2800 1 rpm (current data status, tends toward >2560 rpm) and air mass > 180 mg/unit. It is not possible to clear fault by switching ignition terminals. Compliance with the activation conditions and absence of malfunction extending over several seconds are required before fault code can be cleared.