12 14 522 Replacing Pulse Generator On Left Inlet Camshaft (N62, N62TU)
(cylinder bank 5 to 8)
Necessary preliminary tasks:
- Read out fault memory of DME control unit; if necessary, work through test schedules
- Switch off ignition
- Remove ACOUSTIC COVER
- Remove left ignition coil cover
Release plug connector (1) and pull off.
Release screw.
Remove pulse generator (2).
Installation:
Replace sealing ring and coat with antiseize agent.
NOTE:
Now clear the fault memory.