Special tools required: 

Necessary preliminary tasks: 

WARNING: Scalding hazard!
Only perform this task on an engine that has cooled down.

Unclip monitor sensor cable from fixture (1).

Unlock and detach plug connection (2) for monitor sensor.

Fig 1: Unclipping Monitor Sensor Cable From Fixture
G03267480Courtesy of BMW OF NORTH AMERICA, INC.

Release monitor sensor (1) with special tool 11 7 030.

Fig 2: Releasing Monitor Sensor With Special Tool 11 7 030
G03267481Courtesy of BMW OF NORTH AMERICA, INC.

Installation: 

  1. Tightening torque, see ENGINE - TIGHTENING TORQUES .

Installation: 

  1. Threads of new oxygen sensors are already coated with Never Seize compound.
  2. If an oxygen sensor is reused, only apply a thin and uniform coat of Never Seize compound to thread.
  3. Oxygen sensor section projecting into exhaust system branch must not be cleaned or come into contact with lubricant.

Installation: 

Check function of DME.

Pay attention to cable routing of monitor sensor.