Checking overtravel at outside handle:
- Close rotary striker lock with a screwdriver,
- open rotary striker lock with outside door handle (1),
- outside door handle (1) must be able to open further by measurement (A),
- if measurement (A) is obtained, then OK.
- if measurement (A) is not obtained, readjust rotary striker lock and carry out overtravel check,
- if measurement (A) is still not obtained, you must Bowden cable with carrier.
A min. 2 mm