Home >> BMW >> 2005 >> 330xi Standard >> Repair and Diagnosis (Single Page) >> Body & Frame >> Seats >> General Electrical System - Repair >> Battery >> 61 20... Threshold values for battery inspection of all battery (telephone except for telephone battery)

61 20... Threshold values for battery inspection of all battery (telephone except for telephone battery)

Safety instructions for handling vehicle battery.

Test step 1 - before charging the battery 

TEST STEP 1 - BEFORE CHARGING BATTERY

Charge state 1) Starting capability 2) Test result
Not testable   Charge
less than 50 % 2)   Charge
more than 50 % less than 75 % Charge
more than 50 % more than 75 % 3) Charge
more than 80 % more than 75 % OK.

Test step 2 - after charging the battery 

TEST STEP 2 - AFTER CHARGING BATTERY

Charge condition 1) Starting capability 2) Test result
Not testable   Defective
less than 50 % less than 75 % Charge
more than 50 % more than 75 % Charge
  1. Charge condition and starting power must always be evaluated together
  2. When test charging for more than 5 hours, use charger Gossen CG 32 or Siemens/Gossen VB 801
  3. Fully charge until charge state is more than 80 %.
NOTE: If battery was checked on the positive terminal in the engine compartment, repeat check directly on battery for sake of safety.