Level Curve Of The Zero-Position Sensor: Level Change Between High And Low
The level curve of the output signal corresponds to the degree of overlap of the Hall sensor and the sensor plate.
The output signal is either a high level signal or a low level signal. The level curve is illustrated in the following graphic:
LEVEL CHANGE BETWEEN HIGH AND LOW LEGEND
| Key | Explanation | Key | Explanation |
|---|---|---|---|
| 1 | Mechanical stop | 2 | Encoded end stop of range of movement |
| 3 | Parked position | 4 | Position at which a level change is expected (with a minor switching delay) |
| 5 | Straight-ahead position = 0° | 6 | Encoded end stop of range of movement |
| 7 | Mechanical stop | 8 | Level curve of the zero-position sensor (Hall sensor): |