LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2004 >> 530i Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 612 (HEATING & AIR CONDITIONING - REPAIR INSTRUCTIONS - 525i) >> Troubleshooting >> 64 99... Fault 06 Park heating metering pump

64 99... Fault 06 Park heating metering pump

WARNING: This page is about a different car, the 2003 BMW 525i, 2002 BMW 525i, and 2001 BMW 525i. However, it is still accessible from the selected car via links, so may be relevant.

Test precondition: 

Overheating protection not active. Voltage supply at independent parking heater OK.

Coolant temperature < 40 ° C

Vehicle tank adequately filled.

Instruction: 

Switch on independent parking heater via MID or on-board monitor.

Check clock pulse at metering pump 32 seconds after switching on independent parking heater.

PARK HEATING METERING PUMP FAULT DESCRIPTION

Question Answer Measure
Can clock pulse be heard at metering pump? No Fault 6.1
Yes Disconnect fuel hose at independent parking heater and start independent heater several times if necessary until fuel emerges at heater connection. To measure delivery capacity, start independent parking heater twice and measure fuel quantity for 60 seconds at a time. Project metering quantity for 1 hour.
Is a metering quantity of 650 ml/h +/- 10% reached? No Fault 6.2
Yes The metering pump is OK