12 42 550 Removing and installing/replacing between battery positive lead between starter motor and jump start terminal (M54)
WARNING: This page is about a different variant/trim than selected.
Interrogate fault memory of DME control unit.
Switch off ignition.
Observe instructions for disconnecting and connecting battery. Refer to 12 00... INSTRUCTIONS FOR DISCONNECTING AND CONNECTING BATTERY .
Disconnect negative battery lead.
Release nut.
Fold down protective cap (1).
Release nut.
Tightening torque, (21 N.m).
Remove battery positive lead from positive support point for jump starting.
Remove cover from fuel injectors.
Unclip battery positive lead (1) from holder (2).
Release nut (2).
Tightening torque, refer to 12 41 4AZ in ENGINE ELECTRICAL SYSTEM - TIGHTENING TORQUES .
Detach battery positive lead (2) from starter motor and remove.
NOTE:
For purposes of clarity, reinforcement plate is now shown.
Do not remove reinforcement plate.
NOTE:
Interrogate fault memory of DME control unit.
Check stored fault messages.
Rectify faults.