12 14 521 Replacing pulse generator on crankshaft (M54/M56)
Necessary Preliminary Tasks:
- Read out fault memory of DME control unit.
- Switch off ignition.
All models:
NOTE:
Installation location of pulse generator for crankshaft is underneath starter motor.
NOTE:
For a better overview, this work step is shown on an engine that has been removed.
Unlock plug (1) and remove.
Unscrew bolt (2).
Remove pulse generator (3).
NOTE:
Check stored fault messages.
Now clear the fault memory.