17 00 039 Venting cooling system and checking for leaks (N62)
Open sealing cap only after engine has cooled down.
No vent plugs on radiator and thermostat housing.
Cooling system is vented while it is filled and during subsequent idle operation.
Important: The auxiliary water pump must deliver coolant in order to ensure fully venting!
Installation:
Use only recommended coolant.
Check cooling system for leaks. Refer to 17 00 009 Checking cooling system for leaks (N62) .
Illustration shows E65/E66:
Perform filling operation slowly.
Pour coolant into expansion tank (1) up to MAX mark.
Start engine and run at idle speed for approx. one minute (cap open). Then adjust coolant level to MAX.
Close cap and run engine up to operating temperature until main thermostat opens. Check cooling circuit and drain plug for leaks.
Illustration shows E60/E61/E63/E64:
Perform filling operation slowly.
Pour coolant into expansion tank up to MAX mark.
Start engine and run at idle speed for approx. one minute (cap open). Then adjust coolant level to MAX.
Close cap and run engine up to operating temperature until main thermostat opens. Check cooling circuit and drain plug for leaks.
Check coolant level and adjust to MAX.