12 14 526 Replacing pulse generator on right inlet camshaft (M62): Notes
Interrogate fault memory of DME control unit.
Switch off ignition.
Remove intake hose refer to 13 54 250 REPLACING INLET HOSE .
Disconnect plug connection (3) on right cable strip.
Release screw.
Remove pulse generator.