12 14 522 Replacing pulse generator on left inlet camshaft (M62): Notes
Interrogate fault memory of DME control unit.
Switch off ignition.
Turn fasteners on acoustic cover 90° counterclockwise.
Remove acoustic cover.
Disconnect plug connection (1) on left cable strip.
Unclip cable from cable holder (2).
Release screw (3).
Remove pulse generator (4).