LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2000 >> M5 >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Base Instrument Cluster (Kombi) - Overview >> Base Instrument Cluster (Kombi) >> Base Instrument Cluster >> Base BC/Instrument Cluster Test Functions >> Test No. 20

Test No. 20

Average fuel consumption - correction factor

The factor follows previous systems, with adjustment range of 750 to 1250. The adjustment method is new for the base cluster. If adjustment is necessary, enter into test 20 using the cluster button. The correction factor number is changed by using the sub-tests for the "ones, tenths and hundreds of the factor number. The digits will automatically scroll through 0-9 within each group (ones, tenths, hundreds).

Sub-Tests:

XXX9 20.0  = Press the button when the correct "ones" position is attained.

XX5X 20.1  = Press the button when the correct "tenths" position is attained.

12XX 20.2  = Press the button when the correct "hundreds" position is attained.