BC Test Functions (IKE E38, E39, E53): Notes
The BC test functions are used to check inputs, outputs and functions of the IKE. There are 21 possible test steps. With the exception of Test # 1,, # 2, and # 19, all other tests are locked but can be released through test # 19.
The test functions are displayed in the instrument cluster. Test number 01 is called up by pressing the CC button for 10 sec. The same activation can be initiated by pressing and holding the CC button while switching on the ignition.
Each time the CC button is pressed, the next test number is displayed.
After selecting a test number, the information from the test is posted by pressing the trip odometer reset button. Several tests have sub-functions which are called up by pressing the reset button while in the test.
Unlocking test functions:
- Call up test # 19 - This is automatically done if attempting to enter a locked test
- Using the trip meter reset button enter by pressing the sum of the last 5 digits of the chassis number, example: VIN GB11111, - 1 + 1 + 1 + 1 + 1 = 5, press the reset button 5 times.
- Confirm entry by pressing the CC button.
The test function can be cancelled by switching the ignition off or pressing the CC button for approximately 2 seconds.