34 52 535 Removing and installing/replacing rear ABS pulse generator: Installation:
Ensure proper locking of the plug connector and proper seating of the cable in the brackets.
Release hexagon socket head cap screw (1), pull ABS pulse generator out of bore.
Tightening torque, refer to 34 51 6AZ MECHANICAL - HYDRAULIC CONTROL .
Clean hole for impulse sensor and grease with lubricating grease Staburags NBU 12/K.