Version with single-spark ignition coils:
Mount special tool 12 7 041 on ignition coils and connect to special tool 12 7 043.
Connect DIS Tester with RZV connecting lead to last test adapter (RZV = static ignition distribution).
Connect trigger pliers of DIS tester to feed line on ignition coil of 1st cylinder.
- Select "Measurement".
- Select "Preset measurements".
Subsequent procedure in accordance with DIS instructions.