LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 1998 >> 540i Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 183 (HEATING & AIR CONDITIONING - REPAIR INSTRUCTIONS - 525i) >> Air conditioning System >> 64 50... Leak-testing with leak tester device

64 50... Leak-testing with leak tester device

WARNING: This page is about a different car, the 2003 BMW 525i, 2002 BMW 525i, and 2001 BMW 525i. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: Avoid contact with refrigerant.
Follow safety precautions when handling refrigerant.

Carry out leak-testing with a leak tester device from the workshop equipment catalog following the device manufacturer's operating instructions.

If leaks not to be localized are already identified during evacuation, the A/C system must nevertheless be filled. Then test for leaks with leak tester device.

NOTE: Refrigerant is heavier than air.
Therefore always conduct the leak test below the lines and components to be tested.
Shield lines and components against strong blasts of air (wind, drawing off).

Tighten down loose lines, mark leaks.

Then draw off draw off A/C system and seal off or repair leakage points.

Then refill A/C system and test for leaks.