Extension Housing: Disassembly
Install extension housing on Counter Support Holder (24 0 190) and clamp holder in vise. Remove "O" ring from extension housing. Unstake output flange slotted nut and remove slotted nut with Insert (24 4 110). Remove snap ring from output flange and lift off extension housing. Using a press, remove output shaft seal and bearings.