DTC 41: Diagnostic Line RXD Has A Break Or Short To Battery Or A Short To Ground: Explanation
The diagnostic line RxD has a break or a short to battery voltage or short to ground. Wire leads from diagnostic socket pin No. 15 to AEGS control unit pin No. 13 (it is connected to terminal No. 30 when the diagnostic cover is closed).