Output Gear Of The Spur Gear Unit, Removing And Installing: Removing
-- Remove the hydraulic pressure reservoir. Refer to GEAR ACTUATOR MODULE AND HYDRAULIC PRESSURE RESERVOIR, REMOVING AND INSTALLING .
-- Remove the circlip from the pinion.
-- Install the puller -3- with nuts -4- on the output gear -1-.
Conditions
- The puller with nuts -4- must not touch a housing rib!
-- Warm up the output gear -1- to approximately 100°C (212 °F) by using a hot air gun.
-- Counterhold on the puller -arrow- when removing.