Coolant Pipe On Heat Pump Valve Unit, Removing And Installing: Installing
Install in the reverse order of removal while noting the following:
- Secure all hose connections with hose clamps that match the ones used in series production. Refer to the Parts Information.
- Used coolant cannot be used again.
- Replace the O-rings. Refer to REFRIGERANT CIRCUIT SEALS .
-- Fill the cooling system. Refer to COOLING SYSTEM, FILLING, HIGH-VOLTAGE SYSTEM COOLING CIRCUIT .
-- Check the routing after securing refrigerant lines. They must be inserted in their brackets and must not come into contact with other components.
-- Drain and fill the refrigerant circuit. Refer to Refrigerant Circuit (Refrigerant R134a Servicing, Refrigerant Circuit, Working with A/C Service Station) or Working with A/C Service Station .
-- Switch the ignition on.
-- Initiate the basic setting of the A/C system using the Thermal Management Control Module -J1024- and activate the electric valves using the routine Stop routine refrigerant circuit filling/flushing in the Vehicle Diagnostic Tester in the Guided Fault Finding function.
-- Start the A/C system after charging the refrigerant circuit. Refer to A/C SYSTEM, STARTING AFTER CHARGING REFRIGERANT CIRCUIT .