A/C System, Starting After Charging Refrigerant Circuit
Starting the A/C system after charging the refrigerant circuit must be performed under the following circumstances:
- The A/C compressor was replaced and the refrigerant circuit was flushed.
- Refrigerant circuit was flushed.
- The electrical A/C compressor was replaced.
-- Make sure that a minimum of 50% of the required amount of refrigerant oil for the refrigerant circuit is in the A/C compressor.
-- All removed parts are reinstalled.
-- The refrigerant circuit is charged. Refer to A/C SYSTEM, GENERAL INFORMATION or REFRIGERANT CIRCUIT, CHARGING .
-- Open all instrument panel vents and, if present, the vents in the center console.
-- Switch the ignition on.
-- Perform the basic setting for the A/C and heating electronics (A/C compressor intake routine) using the Vehicle Diagnostic Tester.
Procedure
-- Connect the Vehicle Diagnostic Tester.
-- Select the Diagnostic mode and start the diagnosis.
-- Select the Test plan tab.
-- Select the Select individual test button and select the following tree structure consecutively:
- Diagnostic-capable systems
- 0008 - A/C/Heater Electronics
- 0008 - A/C/Heater Electronics Functions
- 0008 - Basic Setting
-- Let the A/C compressor run with the engine in idle for at least five minutes.