Plenum Chamber Bulkhead, Removing And Installing: Installing
Install in the reverse order of removal while noting the following:
-- Remove the foam seal and remove any adhesive residue.
-- Clean the plenum chamber bulkhead with Cleaning Solution:D 009 401 04 .
-- Push on the new plenum chamber bulkhead seal and shorten if necessary. Refer to Parts Information.
- Make sure the seal between the plenum chamber bulkhead and the body is seated correctly.
Vehicles with High-Voltage System:
There is a risk of fatal injury due to high voltage.
Electrocution by direct contact or electric arc can cause severe bodily injury or fatal injury.
- Have an Audi high-voltage technician or an Audi high-voltage expert bring the high-voltage system back into service.
-- Re-energize the high-voltage system. Refer to appropriate Repair Information .
-- Fill the coolant and bleed the system. Refer to COOLANT, DRAINING AND FILLING .