LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2024 >> S3 Premium >> Repair and Diagnosis >> External Pages >> Different car >> Section 273 (Cooling System (4-Cylinder Direct Injection 2.0L 4V TFSI Engine (Ea 888EVO4))) >> 19 Cooling System >> Coolant Pump/Coolant Thermostat >> Thermal Management Coolant Temperature Sensor 6 -G907-, REMOVING AND INSTALLING >> Thermal Management Coolant Temperature Sensor 6 -G907-, REMOVING AND INSTALLING, AUDI A6/A7

Thermal Management Coolant Temperature Sensor 6 -G907-, REMOVING AND INSTALLING, AUDI A6/A7

WARNING: This page is about a different car, the 2024 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Procedure 

-- In order to reduce the remaining pressure in the cooling system, cut the seal strap -1- and open the high-voltage system cooling circuit coolant expansion tank cap -5-.

Fig 2: Coolant Hose Tightening Sequence
GWWA19-12692Courtesy of AUDI OF AMERICA, LLC

-- Free up the wiring harness.

GWWA19-13642Courtesy of AUDI OF AMERICA, LLC

-- Lift the clamps -2 and 3-, remove and free up the coolant hoses.

-- Disconnect the connector -5- for the Engine Coolant Level Sensor -G32-.

-- Remove the bolt -4-, move the coolant expansion tank to the side.

-- Disconnect the connector -5-.

GWWA19-13182Courtesy of AUDI OF AMERICA, LLC
CAUTION:

Collecting coolant and determining volumes.

-- Place the Shop Crane - Drip Tray:VAS 6208  underneath.

-- Disconnect the coolant hose -3- with Hose Clamps - Up To 25mm:3094  .

-- Disconnect and remove the coolant hose -2- with Hose Clamps - Up To 25mm:3094  , to do this, loosen the hose clamp.

-- Remove the bolt -4-, and remove the Thermal Management Coolant Temperature Sensor 6 -G907- -item 1-.

-- To prevent coolant loss, install the new coolant temperature sensor immediately.

-- Add the coolant. Refer to COOLANT, ADDING AND COOLING SYSTEM, BLEEDING, HIGH-VOLTAGE SYSTEM COOLING CIRCUIT .

-- Drain and fill the coolant for the high-voltage system cooling circuit only if the coolant loss is greater than 500 ml. Refer to COOLANT, DRAINING, HIGH-VOLTAGE COOLING CIRCUIT  and Refer to COOLING SYSTEM, FILLING, HIGH-VOLTAGE SYSTEM COOLING CIRCUIT .

Tightening Specifications