Vacuum, Checking

WARNING: This page is about a different car, the 2024 Audi S6 and 2024 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

TIP:

-- Connect the Brake Servo Tester:VAS 6721  . Refer to BRAKE BOOSTER TESTER, CONNECTING .

-- Open the shut-off valve -A-.

Fig 1: Identifying VAS 6721 Shut-Off Valves
GWWN47-10210Courtesy of AUDI OF AMERICA, LLC

-- Close the shut-off valves -B and C-.

-- Start the warm (greater than 60 °C (140 °F)) engine and press the accelerator pedal once briefly (engine speed higher than 2, 000 RPM).

-- Read the displayed measured value.

-- Create a vacuum using the Hand Vacuum Pump:VAS 6213  for comparison. Refer to VACUUM, CREATING WITH HAND VACUUM PUMP .

-- Opening the shut-off valve -B- makes it easier to remove the hose connections and the adapter.