Home >> Audi >> 2024 >> S3 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 9 (Air Conditioning (Refrigerant R1234YF Servicing) (Refrigerant Circuit)) >> 87 Air Conditioning >> Refrigerant Circuit >> Leaks, Finding >> Refrigerant Circuit, Finding Leaks Using Electronic Leak Detector >> Perform a leak detection test on a refrigerant circuit that is filled with refrigerant:

Perform a leak detection test on a refrigerant circuit that is filled with refrigerant:

WARNING: This page is about a different car, the 2022 Audi S3, 2022 Audi RS 3, 2022 Audi A3 Quattro, and 2022 Audi A3. However, it is still accessible from the selected car via links, so may be relevant.

-- On vehicles with a high-voltage system, switch off (deactivate) the "auxiliary climate control" function. Refer to the Owner's Manual and Infotainment/MMI Operating Manual.

-- Switch off the ignition.

-- Start up the leak detector in line with relevant operating instructions.

-- Always hold the test probe underneath the suspected leak.

Fig 1: A/C Refrigerant System, Checking For Leaks
GWWV87-1455Courtesy of AUDI OF AMERICA, LLC

Depending on the model, leak detection is indicated by an increase in clicking rate or a warning tone. Refer to the Leak Detection Device Owner's Manual.

NOTE:

Currents of air quickly disperse refrigerant gas. Drafts must therefore be avoided during leak detection.

Refrigerant gas is heavier than air and will escape.