Lane Change Assistance, Calibrating, Stationary Calibration
Calibration/adjustment must be performed if:
- The installation position of the Lane Change Assistance Control Module -J769- / Lane Change Assistance Control Module 2 -J770- in the vehicle has been changed.
- The rear bumper cover was removed and installed or replaced.
- The rear bumper cover was painted near the control modules.
Special tools and workshop equipment required
- Calibration Unit:VAS6350A
- Calibration Tool - Spacing Laser:VAS6350/2A
- Calibration Tool - Lane Change Calibration Tool:VAS6350/4
- Vehicle Diagnostic Tester
Preparing for Calibration
- Calibration Tool - Spacing Laser:VAS6350/2A
- For distance measurement
- Refer to the Calibration Tool - Spacing LaserVAS6350/2A Operating Instructions for handling.
- Calibration Board
- Level
- On the calibration board
- For checking horizontal position of calibration platform
- Catch Bracket
- To mount the Spacing Laser:VAS6350/2A for the distance measurement
- Distance to the Calibration Tool - Wheel Center Mounting:VAS6350/1A on the rear wheels: dimension -a- = 1700 ± 2 mm
- Calibration Tool - Lane Change Calibration Tool:VAS6350/4
- Is moved from one side of the measuring field to the other during calibration
- When installed correctly, the vehicle electrical system voltage line must be connected at lower left of the calibration device (as seen in direction of travel)
- Emblem
- The linear laser is aligned to the center of the emblem
- Calibration Tool - Wheel Center Mounting:VAS6350/1A
- With wheel bolt adapter and measuring paddle
- Measuring Scale
- For positioning the Calibration Tool - Lane Change Calibration Tool:VAS6350/4
- Calibration Tool - Linear Laser:VAS6350/3A
- With "laser protective eyewear"
- On the calibration board
- Refer to Calibration Tool - Line LaserVAS6350/3A Service Information for handling.
- Plastic Foot
- Adjustable for aligning horizontal position of the calibration board
- Quantity: 3
Requirements
- Move the vehicle onto a solid, flat surface.
- Move the wheels so that they are straight.
- Deflect and swing out the vehicle multiple times.
- Electromechanical parking brake applied.
- The vehicle exterior lamps are off.
- People must not sit in the vehicle.
- All vehicle doors and the rear lid must be closed.
- Remove the label with the metal foil from the bumper cover, if necessary.
- Connect the battery charger for the battery support mode. Refer to BATTERY, CHARGING .
- Before starting the calibration/adjustment, check the DTC memory and correct all displayed entries.
Procedure
-- Check which hole circle the rims have.
-- Secure three suitable wheel bolt adapters for the wheel bolts on each Calibration Tool - Wheel Center Mountings:VAS6350/1A .
-- Insert the measuring paddle at both Calibration Tool - Wheel Center Mounting:VAS6350/1A and secure with the locking nut.
-- Place the Calibration Tool - Wheel Center Mountings:VAS6350/1A onto the wheel bolts on both rear wheels.
- The wheel center mounting rotation center must be in the wheel rotation center.
-- Place the Calibration Tool - Wheel Center Mounting:VAS6350/1A on the wheels so that any anti-theft wheel bolts are not connected to the wheel center mounting.
-- Adjust the measuring paddle using the locking nuts so that they move freely just above the floor.
- The measuring paddles must move easily.
- The measuring paddles must be vertical.
-- Position the calibration tool at distance -a- to the rear wheels.
- Dimension -a- = 1, 700 mm
-- Using the bubble level (level indicator) -arrow-, bring the calibration tool into a horizontal position by turning the plastic bases.
-- Wear "laser protective eyewear".
-- Turn on the Calibration Tool - Linear Laser:VAS6350/3A on the calibration tool.
-- Align the calibration tool so that the Calibration Tool - Linear Laser:VAS6350/3A strikes the center of the emblem on the rear lid.
-- Turn on the Calibration Tool - Spacing Laser:VAS6350/2A . Refer to Calibration Tool - Spacing LaserVAS6350/2A Operating Instructions.
Indicator on the display -1- :
The display -2- shows how to position the Calibration Tool - Spacing Laser:VAS6350/2A .
- -arrow 1- : position with front edge
- -arrow 3- : position with rear edge
-- Press the corresponding button.
-- Hold the Spacing Laser:VAS6350/2A -2- for the distance measurement on one side of the calibration board flush to the catch bracket, as shown.
- The Calibration Tool - Spacing Laser:VAS6350/2A -2- must lie firmly against the catch bracket.
-- Push the measurement button briefly.
The laser switches on.
-- Make sure the "laser beam" for the distance measurement contacts the lower enlarged part of the measuring paddle -1-.
If that is not the case, correct the measuring paddle -1- height using the clamping screw on the Calibration Tool - Wheel Center Mounting:VAS6350/1A .
-- Use one hand to hold the Calibration Tool - Spacing Laser :VAS6350/2A firmly in the catch bracket on the calibration tool the laser beam should be seen on the measuring paddle during this.
-- Then press the measurement button for the distance measurement briefly.
Display on Calibration Tool - Spacing Laser:VAS6350/2A :
- "1, 700 m (5, 577.4 feet)" (specified value: 1700 ± 2 mm).
-- Repeat this measurement on the other side of the calibration tool in the same way for the rear wheel.
- The distance value must be the same on both sides.
-- If both measured values are not the same, then readjust the calibration tool correspondingly until the distance values are the same on both sides.
-- Make sure the Calibration Tool - Line Laser:VAS6350/3A strikes the center above the emblem and that the level indicator remains centered. Adjust if necessary.
Calibration Procedure
The following should not occur during the calibration procedure:
- No metallic reflectors may be located within a 2 m (6.6 feet) radius of the calibration tool (meaning tool carts, metal cabinets).
- Vehicle doors must not be opened or closed.
- Individuals must not go between the vehicle and the calibration tool.
-- Connect the Vehicle Diagnostic Tester. Refer to Vehicle Diagnostic Tester.
-- Switch the ignition on.
-- Select and start the Diagnostic operating mode.
-- Select the Test plan tab.
-- Select the Select individual test button and select the following tree structure consecutively:
- Diagnostic-capable systems
- 003C - Lane Change Assistance - Rear Radar Entry Gen3
- 003C - Blind Spot Assistance Control Module, Functions
- 003C - Calibration
-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.
TIP:
The following information clarifies which version of the lane change assistance is installed in the vehicle (version HRE3.0).
-- Secure the Calibration Unit for Lane Change Assist:VAS6350/4 to the left rear side on the mount of the calibration tool.
- When installed correctly, the vehicle electrical system voltage wire must be connected at the bottom left of the calibration device (as seen in direction of travel).
Dimension -a- is measured from the upper edge of the calibration device to the floor.
| Model | Audi A3 |
|---|---|
| Adjustment Dimension Height In Mm Dimension -a- | 839 |
-- The indicator on the base of the Calibration Tool - Lane Change Calibration Tool:VAS6350/4 must align with the adjustment dimension on the measuring scale -1- on the measuring field -arrow-.
| Model | Audi A3 |
|---|---|
| Left Adjustment Dimension Read In Mm On The Measuring Scale -1- | 900 |
-- Connect the Calibration Tool - Lane Change Calibration Tool:VAS6350/4 -1- to the vehicle electrical system voltage and switch it on at the voltage switch -2-.
- The green LED -4- must turn on.
-- If the red LED -3- turns on, then check the Calibration Unit for Lane Change Assist:VAS6350/4 -1-.
-- Follow the instructions in the Vehicle Diagnostic Tester display.
During the program sequence, there is a prompt to switch the Calibration Tool - Lane Change Calibration Tool:VAS6350/4 from the left to the right side of the calibration tool.
-- Turn off the Calibration Tool - Lane Change Calibration Tool:VAS6350/4 and reposition the calibration tool.
- When installed correctly, the vehicle electrical system voltage wire must be connected at the bottom left of the calibration device (as seen in direction of travel).
Dimension -a- is measured from the upper edge of the calibration device to the floor.
| Model | Audi A3 |
|---|---|
| Adjustment Dimension Height In Mm Dimension -a- | 839 |
-- The indicator on the base of the Calibration Tool - Lane Change Calibration Tool:VAS6350/4 must align with the adjustment dimension on the measuring scale -1- on the measuring field -arrow-.
| Model | Audi A3 |
|---|---|
| Right Adjustment Dimension Read In Mm On The Measuring Scale -1- | 900 |
-- Connect the Calibration Tool - Lane Change Calibration Tool:VAS6350/4 -1- to the vehicle electrical system voltage and switch it on at the voltage switch -2-.
- The green LED -4- must turn on.
-- Follow the instructions in the Vehicle Diagnostic Tester display.
-- Switch off the ignition after successful calibration.
-- Disconnect the Vehicle Diagnostic Tester from the diagnostic connection.
-- Disconnect the battery charger. Refer to BATTERY, CHARGING .