Refrigerant Lines, Disconnecting And Connecting From Condenser: Installing
Install in the reverse order of removal while noting the following:
-- Replace the O-rings. Refer to the Parts Information for the version.
-- If equipped, check the alignment pin -4- for damage and correct seating.
-- Check the guide ring -2- on the refrigerant line connection for damage.
-- Insert the O-ring -3- into the groove -arrow- on the refrigerant line connection -1-.
-- Coat the O-rings with refrigerant oil before installing. Refer to SEALS AND GASKETS .
-- Check the refrigerant pipes leading to the evaporator for contamination and damage.
-- Make sure the O-rings fit correctly inside the groove on each refrigerant line.
- Routing and securing the refrigerant lines. Refer to LINE ROUTING AND SECURING .
-- Evacuate and charge the refrigerant circuit. Refer to Refrigerant Circuit or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .